● Reference Voltage: 220V
● Input Current: 10(60)A
● Small Compact Size
● Diverse Electricity Parameters Measurement
● DIN Rail Installation
● LCD Display
● RS485 (MODBUS-RTU)
● IEC62053-21:2003; IEC62053-22:2003; CE; EAC

    OVERVIEW

    ADL10 din rail energy meter adopts DIN35mm din rail installation with LCD display,it can measure electric parameters and has energy pulse output, RS485 communication,which has the advantages of small size, high precision, good reliability and convenient installation.

    MAIN PARAMETERS

    Functions

    Function

    Function description

    Function provide

    Measurement of kWh

    Single-phase active kWh (positive and negative)

    Measurement of electrical parameters

    Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency

    LCD Display

    8 bits section LCD display

    Communication

    Communication interface: RS485, Communication protocol: MODBUS-RTU

     

    Electric performance

    Input voltage

    Reference voltage

    AC220V

    Reference frequency

    50Hz

    Power consumption

    <10VA

    Input current

    Basic current

    10A

    Maximum current

    60A

    Starting current

    0.004Ib

    Consumption

    <4VA  (Maximum current)

    Measurement performance

    Accuracy of measuring

    1 Class

    Range of measuring

    000000.00~999999.99kWh  

    Communication

    Interface

    RS485(A+、B-)

    Connection mode

    Shielded twisted pair conductors

    Protocol

    MODBUS-RTU

     

    Mechanical performance

    Outline (Length × Width × Height)

    18mm×96 mm×70mm

     

    Work environment

    Range of temperature

    Working temperature

    -25℃~55℃

    Storing temperature

    -40℃~70℃

    Relative humidity

    ≤95%(No condensation)

     Altitude

    <2000m

    FUNCTIONS

    features-13bb

    Small Compact Size
    ● Dimension (L*W*H): 18mm*88mm*70mm

    features-2crv

    DIN Rail Installation
    ● U (Voltage)
    ● I (Current)
    ● P (Power)
    ● Q (Reactive power)
    ● S (Apparent power)
    ● PF (Power factor)
    ● kWh (Kilowatt-hours)
    ● kVarh (Kilovar-hours)
    features-3jz6

    DIN Rail Installation
    ● 35mm standard DIN rail

    features-4nzf

    LCD Display
    ● 8 digits
    features-53pp

    DISPLAY

    displayep7

    PACKAGE


    MINIMUM PACKAGE

     

     package-1xle

     package-2ujn

     

    MINIMUM PACKAGE

     

    Package dimensions(4 PC)

    170*150*130mm

    Net Weight(0.083KG/PC*4)

    0.332Kg

     

    WHOLE BOX PACKAGE

     

    Package dimensions(36 PCS)

    480*460*200mm

    Package Weight(36 PCS)

    4.069KG

     

    PRODUCT HS CODE

     

    9028301400

    APPLICAITON

    1705901510544dc8
    17059015170119ut
    common application-3ina
    common application-4t7m

    APPLICAITON SCENARIOS

    application scenariolts

    TYPICAL CONNECTION

    connectionkqc

    WIRING DIAGRAM

    wiring-1esn
    wiring-2g2y

    WIRING DIAGRAM

    Step ①: Correctly install&wire meters
    1. 35mm DIN-rail installation
    2. 3-phase 4-wire or 3-phase 3-wire methods
    3. Voltage signal input via direct connect or PTs
    4. Current signal input via CTs or Rogowski Coils
    5. Power supplied by 85~265Vac L-N power source
    1705903304149p2k

    Step ②: Download&Register IoT APP
    1. Introduction of IoT Energy Monitoring Solution (IoT EMS)
    2. Introduction of IoT EMS APP (for mobile users)
    3. Introduction of IoT EMS WEB (for PC users)
    4. Download of IoT EMS APP
    5. Register your account with 3-month Free Trial
    6. Or contact us to get Test Account
    1705903320437zqt

    Step ③: Add Meters to your Account
    1. Meters are recognized by unique SN code
    2. Scan QR code to add meter to your account
    3. Edit CT&PT ratio according to paired CT&PT
    4. If voltage input via direct connect, PT ratio set to 1 (Actual Power System Voltage = Voltage Signal Input of Meter)
    5. If current input via 250A/5A CTs for example, CT ratio set to 50 (250÷5=50)
    17059033975738dg

    Step ④: Start your 3-month Free Trial
    1. After 3 months, host service&buy-out service will be available for account renewal
    2. Contact us for more information about system charge item&meter quotation
    3. Before we send you the quotation, we will set a solution acoording to your request
    4. Provide full technical support for installing meters and connecting meters to our system
    1705903405381r0m
    Download_file
    [Certificate 2023.06.21] CE Certificate of ADW300 Series
    Download_file
    [Certificate 2023.06.21] CE-RED Certificate of ADW300 Series
    Download_file
    [Certificate 2023.06.21] IEC Certificate ADW300 Series
    Download_file
    [Certificate 2023.06.21] LVD Certificate of ADW300 Series
    Download_file
    [Datasheet 2023.06.21] ADW300 3-phase Wireless Energy Meter
    Download_file
    [Instruction 2023.08.31] ADW300 Common FAQ & Trouble Shooting
    Download_file
    [Instruction 2023.08.31] ADW300 Keypad Configuration Manual