AMC100-FDK Series DC Outgoing Line Monitoring Device(With Switch Status Monitoring)

Precision Power Distribution Monitoring

Products Categories
Featured Products

AMC100-FDK Series DC Outgoing Line Monitoring Device(With Switch Status Monitoring)

● AMC100-FDK30 30 channels DC monitoring&AMC100-FDK48 48 channnels DC monitoring

● A+B Independent 2 outlets

● 180mm/144mm Size

● A and B all have 24/15 outlets full electrical parameter measurement

● 48/30 outlets active switch input

● 1 RS485

    OVERVIEW

    AMC100-FDK Series DC Outgoing Line Monitoring Device(With Switch Status Monitoring) can monitor the full power parameters and switching status(active) of A+B dual DC outlet 48 branches, and 1 RS485 communication.
    Acrel AMC100 series AC precision power distribution monitoring device is a measuring device designed specifically for power management of data center servers. The device is compact and can monitor the full electrical parameters, input and output switches and the status of the lightning arrester of A+B two incoming lines and 192 outgoing lines in real time. The alarm thresholds of all measurement channels can be set individually.For the outgoing line ,the limited event triggers the system's sound and light alarms immediately.The whole solution realized the high integration of the monitoring circuits in the volume of the traditional instrument.

    MAIN PARAMETERS

    Instrument model

    AMC100-FDK30

    AMC100-FDK48

    Measuring parameters

    Voltage,Current,Power,Electric energy

    Bus voltage

    Rated

    48VDC,240VDC,336VDC

    Measuring range

    ±20%

    Overload

    Instantaneous voltage 2 times per second

    Current
    incoming circuit

    Rated

    5V(Hall sensor,need external power supply±12V or±15V)

    Range

    Overload

    Duration is 1.2 times,instantaneous 10 times/second

    Measuring
    accuracy

    coil out

    Voltage/current level 0.5,power/electric energy level 1


    Auxiliary supply

    Powered by AMC100-ZD;DC 12-24V power supply when used alone

    Environment

    Temperature

    Operation:-15℃~55℃          Storage:-25℃~70℃

    Humidity

    Relative humidity≤93%

    Altitude

    ≤2500m

    Communication

    RS485/Modbus-RTU

    Installation

    Method DIN35mm rail or bottom plate installation

    Protection level

    IP20

    Pollution level

    2

    Security

    Insulation

    The insulation resistance between all terminals and the conductive parts on
    the shell must be at least 100MQ

    Withstand voltage

    Voltage and current signal of line A//Voltage and current signal of line B//
    The two of other ports meet AC2kV for 1min,the leakage current should be
    less than 2mA,and no breakdown or flashover phenomenon

    Electromagnetic
    compatibility

    Antistatic
    interference

    Level 4

    Radio frequency
    electromagnetic
    radiation

    Level 3

    The difference between AMC100-FDK30/48 and AMC100-FD30/48 is AMC100-FDK30/48 have the function of outlets status monitoring

    DIMENSION

    dimension-1

    AMC100-FDK48/AMC100-FD48 Dimension

    图片39

    AMC100-FDK30/AMC100-FD30 Dimension

    MATCHED CURRENT TRANSFORMER

    图片42

    AKH-0.66-EMS

    图片40

     

    图片43

    AKH-0.66-9N-HB

    AKH-0.66-12N-HB

    AKH-0.66-20-HB

    AKH-0.66-30N-HB

     图片41

     

    APPLICATION SCENARIOS

    APPLICATION SCENARIOapplication

    WIRING DIAGRAM

    wiring

    INSTALLATION INSTRUCTION

    INSTALLATION

    PHOTOS ON SITE

    photo on site-1

    ①AMC100-FAK30/48 Measure 30/48 channels of each circuit of A+B outgoing line
    ②AMC100-ZA  Measure A+B independent 2 circuits three-phase main incoming line
    ③RS485 communication line
    ④AKH-0.66W Type ct or AKH-0.66-EMS type (50,100,200400A)/50mA
    ⑤AKH-0.66/30I Tpye ct
    ⑥ATP007kt 7-inch Touch screen or ATP010kt 10-inch Touch screen

    photos on site-1photos on site-2

    Download_file
    [Certificate 2023.06.21] CE Certificate of ADW300 Series