Leave Your Message
AMC100-KD Series Dry Contact Switch Status Monitoring Device

Precision Power Distribution Monitoring

Products Categories
Featured Products

AMC100-KD Series Dry Contact Switch Status Monitoring Device

● Monitoring the A+B dual circuit dry contact switch(passive)status of 30/48 channels

● 1 channel RS485 communication

    OVERVIEW

    AMC100-KD series monitoring device is used to monitor the dry contact switch status in data center.
    Acrel AMC100 series AC precision power distribution monitoring device is a measuring device designed specifically for power management of data center servers. The device is compact and can monitor the full electrical parameters, input and output switches and the status of the lightning arrester of A+B two incoming lines and 192 outgoing lines in real time. The alarm thresholds of all measurement channels can be set individually.For the outgoing line ,the limited event triggers the system's sound and light alarms immediately.The whole solution realized the high integration of the monitoring circuits in the volume of the traditional instrument.

    MAIN PARAMETERS

    Instrument model

    AMC100-KD30

    AMC100-KD48

    Auxiliary supply

    Powered by AMC100-ZD;DC 12-24V power supply when used alone




    Environment

    Temperature

    Operation:-15℃~55℃          Storage:-25℃~70℃

    Humidity

    Relative humidity≤93%

    Altitude

    ≤2500m

    Switch input

    30 dry nodes

    48 dry nodes

    Communication

    RS485/Modbus-RTU

    Installation

    Method DIN35mm rail or bottom plate installation

    Protection level

    IP20

    Pollution level

    2

    Security

    Insulation

    The insulation resistance between all terminals and the conductive parts on
    the shell must be at least 100MS

    Withstand voltage

    Voltage and current signal of line A//Voltage and current signal of line B//
    The two of other ports meet AC2kV for 1min,the leakage current should be
    less than 2mA,and no breakdown or flashover phenomenon.

    Electromagnetic
    compatibility

    Antistatic
    interference

    Level 4

    Radio frequency
    electromagnetic
    radiation

    Level 3

    DIMENSION

    dimension-1

    AMC100-KD48 Dimension

    dimension-1

    AMC100-KD30 Dimension

    APPLICATION SCENARIOS

    APPLICATION SCENARIOapplication

    WIRING DIAGRAM

    WIRING KD30-1WIRING KD30-2

    AMC100-KD30 Wiring Diagram

    WIRING KD48-1WIRING KD48-2

    AMC100-KD48 Wiring Diagram

    INSTALLATION INSTRUCTION

    INSTALLATION

    PHOTOS ON SITE

    photo on site-1

    ①AMC100-FAK30/48 Measure 30/48 channels of each circuit of A+B outgoing line
    ②AMC100-ZA  Measure A+B independent 2 circuits three-phase main incoming line
    ③RS485 communication line
    ④AKH-0.66W Type ct or AKH-0.66-EMS type (50,100,200400A)/50mA
    ⑤AKH-0.66/30I Tpye ct
    ⑥ATP007kt 7-inch Touch screen or ATP010kt 10-inch Touch screen

    photos on site-1photos on site-2

    Download_file
    [Certificate 2023.06.21] CE Certificate of ADW300 Series