AMC200(L)-xE3 3-Phase Multi-Circuits Energy Meter
OVERVIEW
AMC200(L) AC multi circuit energy meter is mainly used for the measurement of full electrical parameters of multiple loops, and can access the current input of up to 8 three-phase loops or 24 single-phase loops at the same time. Can measure voltage and current, power, power factor and other parameters.
MAIN PARAMETERS
|
Technical Parameter |
Technical Indicator |
|||
|
Input |
Frequency |
45~65Hz; |
||
|
Voltage |
Rating: AC 3×220V/380V; |
|||
|
Overload: 1.2 times rated (continuous); 2 times rating value/1 second; |
||||
|
Power consumption: ≤0.5VA (per channel); |
||||
|
Current |
Rating: AC xxxA/50mA, need external transformer; |
|||
|
Overload: 1.2 times rated (continuous); 10 times rating value /1 second; |
||||
|
Power consumption: ≤0.5VA (per channel); |
||||
|
Function
|
Pulse Output |
Output mode: open collector optocoupler pulse (default 400imp/kWh); |
||
|
Communication |
Modbus-RTU or YD/T 1363 protocol(use in China);Baud rate 1200~38400; |
|||
|
Switch |
Input |
|||
|
Output |
Output mode: relay normally open contact output; Contact capacity: AC 250V/3A or DC 30V/3A; |
|||
|
NTC Temperature Measurement |
Temperature: -20~100℃ (accuracy ±2℃); |
|||
|
Temp&Humidity Measurement |
Temperature: -20~100℃ (accuracy ±2℃); Humidity: 20-90%RH (accuracy ±5%RH) |
|||
|
Measurement accuracy |
Frequency 0.05Hz, voltage and current 0.5 level, active power 1 level; |
|||
|
Auxiliary power supply |
AC/DC 85 ~ 265V; Power consumption ≤10VA; |
|||
|
Security |
Power Frequency Withstand Voltage |
>AC 2kV/1min; |
||
|
Insulation Resistance |
Input and output end to the housing>100MΩ; |
|||
|
Environment |
Operating temperature: -20℃ ~ +60℃; Storage temperature: -40℃ ~ +70℃; Relative humidity: ≤95% no condensation; Altitude: ≤2500m; |
|||
|
Electromagnetic compatibility |
Surge (impact) immunity test level 4 |
|||
|
Electrostatic discharge immunity test level 3 |
||||
|
Electrical fast transient pulse group immunity test level 3 |
||||
DIMENSION
MATCHED CURRENT TRANSFORMER
|
Type |
Ratio |
Wire length |
Accuracy |
Installation method |
|
AKH-0.66/W-9NY 50A/20mA |
50A/20mA |
(1+0.2)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ10N 50A/20mA |
50A/20mA |
(1+0.2)m |
0.5 Class |
Split type, RJ interface |
|
AKH-0.66 Z-3/*Φ15Y(1/0.5) 100A/50mA |
100A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, trinity, RJ interface |
|
AKH-0.66/W-12NY 100A/50mA |
100A/50mA |
(1+0.2)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ16N 100A/50mA |
100A/50mA |
(1+0.2)m |
0.5 Class |
Split type, RJ interface |
|
AKH-0.66/W-20Y 200A/50mA |
200A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ24N 200A/50mA |
200A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
|
AKH-0.66/W-20Y(1/0.5) 250A/50mA |
250A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/W-30NY 250A/50mA |
250A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ24N 250A/50mA |
250A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
|
AKH-0.66-TD-Φ60-NY |
400A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ36N 400A/50mA |
400A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
|
AKH-0.66-TD-Φ60-NY |
600A/50mA |
(1+0.5)m |
0.2 Class |
Closed type, RJ interface |
|
AKH-0.66/K-Φ36N 600A/50mA |
600A/50mA |
(1+0.5)m |
0.5 Class |
Split type, RJ interface |
WIRING DIAGRAM

Three-phase four-wire voltage and current direct access

Direct access of three-phase three-wire voltage and current

Single-phase voltage and current direct access
Wiring Terminals and Connections
Din Rail Installation