AMC48 Series 4848 AmmeterVoltmeter
OVERVIEW
AMC series programmable ammeter/voltmeter ,adopting AC sampling technology,can directly or indirectly measure electric voltage and current of single phase or three phase grid. It can be used for local display,and connecting industrial control device to form measuring control system.
This series of meters have RS-485 port,adopt Modbus-RTU protocol. Analog output,alarm output,switching input/ output can be selected. Based on different request,by pressing the keys,parameters of ratio,alarm,communication etc. can be modified.
MAIN PARAMETERS
|
Technical parameter |
Value |
||||
|
Input |
Rated value |
AC voltage:Single phaseAC 100V,400V Three phaseAC 100V,400V,660V(UL-L,Only 72/ 96) AC current:AC1A,5A; DC voltage:1000V,300V,75mV,10V; DC current: 0-20mA,4-20mA,5A; |
|||
|
Overload |
Voltage: 1.2 times rated value(continuous); 2 times rated value /1 second Current:1.2 times rated value(continuous); 10 times rated value /1 second |
||||
|
Frequency |
45Hz~65Hz |
||||
|
Power consumption |
Power consumption of each voltage,current input circuit is less than 0.5VA |
||||
|
Accuracy |
0.5 class |
||||
|
Function |
Display |
LED or LCD |
|||
|
Communication |
RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity) Baud Rate 2400/4800/9600/19200 bps etc. |
||||
|
Alarm |
1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc. |
||||
|
Analog |
DC4~20mA,( load <500Ω) (note:Shielded wire is specially selected for the above signal input and output) |
||||
|
switching |
Input |
4 channel or 2 channel dry contact Input,built in power supply |
|||
|
Output |
2 channel switching output,NO relay contact,capacity: 3A/30VDC,3A/250VAC |
||||
|
Auxiliary supply |
Voltage range |
AC/DC 85-265V |
|||
|
Power consumption |
<5VA |
||||
|
Insulation resistance |
≥ 100MΩ |
||||
|
Power frequency withstand voltage |
Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS) Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV |
||||
|
Environment |
Temperature |
Operation: -10℃~+55℃Storage: -25°C ~+70°C |
|||
|
Humidity |
≤95%RH,no condensation,without corrosive gas |
||||
|
Altitude |
≤ 2500m |
||||
FUNCTION
● Collection Function:DI DO collection function
● Control Loop:Through remote signaling, remote control realizes the collection of circuit breakers, limit switches, andrelays, and the control loop.
DIMENSION
DISPLAY
OPTIONAL PANEL SIZE
PACKAGE
|
MINIMUM PACKAGE
|
|
|
|
MINIMUM PAKAGE
|
Package dimensions(1 PC) 170*150*130mm |
Pakage Weight(1 PC) 0.62Kg |
|
WHOLE BOX PAKAGE
|
Package dimensions(16 PCS) 450*245*200mm |
Pakage Weight(16 PCS) 3.66kG |
|
PRODUCT HS CODE
|
9028301400 |
|
APPLICATION SCENARIOS
INSTALLATION INSTRUCTION
PT100 Wiring Method
11~13 are the 1st way terminals of PT100/PT1000, 13~15 are the 2nd way terminals of PT100/PT1000, and so on. PT100/PT1000 is one A wire and two B wires, connect the A wire of PT100/PT1000 to the terminal number marked as A terminal number, and the two B wires are connected to the terminal numbers marked B and C.
NTC Wiring Method
12~13 are the 1st circuit terminals of NTC, 13~14 are the 2nd circuit terminals of NTC, and so on.
Thermocouple Wiring Method
11~12 is the 1st thermocouple terminal, 11 is connected to V-, 12 is connected to V+, 14~15 is the 2nd thermocouple terminal, 14 is connected to V+, 15 is connected to V-, and so on.
0~5V input Wiring Method
11~12 is the 1st thermocouple terminal, 11 is connected to V-, 12 is connected to V+, 14~15 is the 2nd thermocouple terminal, 14 is connected to V+, 15 is connected to V-, and so on.
Communication Terminal
INSTALLATION INSTRUCTION

Embedded Installation

ARTM-8L rail (DIN35mm) installation