Electricity Distrubution
Power Monitoring System
⚫ 35Kv and Below Medium Voltage Swichgear
⚫ Low Voltage Swichgear Products(Incoming)
⚫ Power Quality and Power Factor Correction
⚫ Low Voltage Distribution(Outgoing)
⚫ Distribution Environment Monitoring
Overview
Structure
Medium Voltage Swichgear Products
Model |
Picture |
Features |
Click To Learn More |
AM2SE RMU Protection Relay |
⚫ Protect medium and low voltage switchgear (busbar room, handcart room, cable room) |
||
ARB6 Arc Flash Protection Relay |
⚫ 35-60ms fast action time ⚫ Adopting dual criteria of arc light and current overcurrent ⚫ Accurately locate the fault point, reduce maintenance time, ensure rapid restoration of power supply after accident maintenance |
||
APVIEW500 Power Quality Monitoring Device |
⚫ Steady-state monitoring, transient monitoring, transient monitoring ⚫ Location of sag source ⚫ Voltage sag tolerance curve and analysis ⚫ Fault recording and event recording ⚫ Daily statistics of power quality ⚫ Power quality level assessment report ⚫ Power quality compliance assessment report ⚫ PQDIF data statistics and export ⚫ Marking function ⚫ Websever function |
||
APD UHG Partical Discharge Sensor |
⚫ Bandwidth:300MHz~1600MHz ⚫ Effective height:≥10.5mm ⚫ Interface:SMA ⚫ Connecting cables:Coaxial cable ⚫ Protective class:IP65 ⚫ Installation:Magnetic |
||
ATE400 Wireless Temperature Monitoring Sensor |
⚫ Busbar/Cable.ect temperature monitoring ⚫ Send data to ATC600-C |
||
AHE100 Wireless Temperature and Humidity Monitoring Sensor |
⚫ Monitor Swichgear temperature and humidity ⚫ Send data to ATC600 by lora |
||
ATC600-C Temperature Receiver |
⚫ Receive 240 pcs ATE400/AHE100 Sensor signal ⚫ 50m indoor space monitoring ⚫ Lora communication |
||
ATP007/010 Touch Screen(HMI) |
⚫ Local Display ⚫ Work with ATC600-C |
Low Voltage Swichgear Products(Incoming)
Model |
Picture |
Features |
Click To Learn More |
ATE400 Wireless Temperature Monitoring Sensor |
⚫ Busbar/Cable.ect temperature monitoring ⚫ Send data to ATC600-C |
||
AHE100 Wireless Temperature and Humidity Monitoring Sensor |
⚫ Monitor Swichgear temperature and humidity ⚫ Send data to ATC600 by lora |
||
ATC600-C Temperature Receiver |
⚫ Receive 240 pcs ATE400/AHE100 Sensor signal ⚫ 50m indoor space monitoring ⚫ Lora communication |
||
ATP007/010 Touch Screen(HMI) |
⚫ Local Display ⚫ Work with ATC600-C |
||
APM520 Power Analyzer |
⚫ Panel Mounted Installation ⚫ Harmonics monitoring |
Power Quality and Power Factor Correction
Model |
Picture |
Features |
Click To Learn More |
AnSin Active Power Filter |
⚫ 50-600A ⚫ Fast and real-time tracking and compensation of dynamically changing harmonic currents ⚫ 3P3W/3P4W ⚫ 380V±10% ⚫ 50Hz±2% |
||
AnCos Static Var Generator |
⚫ 30-500Kvar ⚫ Fast and continuous compensation of varying reactive power and negative sequence current ⚫ 3P3W/3P4W ⚫ 380V±10% ⚫ 50Hz±2% ⚫ Linear reactive power compensation |
Low Voltage Distribution(Outgoing)
Model |
Picture |
Features |
Click To Learn More |
APM520 Power Analyzer |
⚫ Panel Mounted Installation ⚫ Harmonics monitoring |
||
ATE400 Wireless Temperature Monitoring Sensor |
⚫ Busbar/Cable.ect temperature monitoring ⚫ Send data to ATC600-C |
||
ARTM-PN Wireless Temperature Monitoring Device |
⚫ Receive and display ATE400 data ⚫ Receive 60pcs ATE400 Sensor ⚫ 5 Panels Share one ARTM-PN |
||
ASJ Earth Leakage Protection Relay |
⚫ A/AC Type Leakage Current Monitoring ⚫ Rated residual action current can be set(0.03-30A) ⚫ Limit non-drive time can be set( (0-10s) ⚫ 2 Sets Relay Output ⚫ Local/Remote/Reset |
||
ARD Series Motor Protection Relay |
⚫ Protection action stage, start shielding time setting function, and action exit setting ⚫ Three voltage, current, power, energy, leakage current, power factor, PTC/NTC/PT100, 2-21st ⚫ HarmonicStart stop record, fault record, running time, number of faults ⚫ MODBUS/PROFIBUS |
||
ARD-KHD Voltage Sag Protection Relay |
⚫ Power shake hold, power shake restart, support energy-saving output mode ⚫ 4DI 4DO ⚫ Harmonic Monitoring ⚫ LCD display |
Distribution Environment Monitoring
Model |
Picture |
Features |
Click To Learn More |
ARTU Remote Terminal Unit |
⚫ Monitor and control DI DO state in distribution like smoke detector,gas detector and .etc. ⚫ Send data to ATC600 by lora |
||
AHE100 Wireless Temperature and Humidity Monitoring Sensor |
⚫ Monitor Swichgear temperature and humidity ⚫ Send data to ATC600 by lora |
||
ATC600-C Temperature Receiver |
⚫ Receive 240 pcs ATE400/AHE100 Sensor signal ⚫ 50m indoor space monitoring ⚫ Lora communication |