Product Attributes

Model No.AMC16

BrandAcrel

Place Of OriginChina

InstallationDIN rail 35mm

MeasurementA+B independent 3 phase circuits, 6DI2DO,2 leakage current,1 temp. and humidity.

Power SupplyWith DC 24V output power supply for outgoing line module and touch screen

CommunicationRS485 Modbus RTU

Supply Ability & Additional Information

PackagingIDC Precision Distribution Monitoring Solution will be packed in carton box with bubble film

Productivity100000 sets per year

TransportationOcean,Land,Air,Express

Place of OriginChina

Supply Ability10000pcs/month

CertificateCE/IEC/UL/MID

HS Code9028301400

PortJiang Yin,Shanghai

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF,EXW,CPT

Packaging & Delivery

Selling Units:
Piece/Pieces
Package Type:
IDC Precision Distribution Monitoring Solution will be packed in carton box with bubble film
Picture Example:

Product Description

IDC Precision Distribution Monitoring Solution

It is necessary to real-time monitor and centralize power consumption in data center and data can be displayed on HMI, and uploaded to the power and environment monitoring system by RS485 on touch screen and realize real-time monitoring of whole power distribution system. At the same time, it can realize energy efficiency analysis to reduce energy consumption.

The Main Functions of IDC Precision Distribution Monitoring Solution is 1.Incoming line and outgoing line circuits independent monitoring modules 2. Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current,voltage,power,energy and Power Quality. 3. Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485.

The related products of data center include: HMI, Dual-circuit Data Center Energy Meter,current transformers, hall effect current sensor, DC Incoming Line Monitoring Module, and DC Outgoing Line Monitoring Module.


Structure

Precision distribution monitoring solution for IDC
Precision distribution monitoring solution for IDC
IDC Precision Distribution Monitoring Solution
Monitoring System For Data Center Energy Management Main Power Supply Module
dc network solution
ac network solution
DC Network Solution AC Network Solution
Main Topography of Precision Distribution System
IDC Precision Distribution Monitoring Solution
Main Topography Of Precision Distribution System Main Power Supply&Backup Power Supply


Main Function

1)Incoming line and outgoing line circuits independent monitoring modules;


2)Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy and power quality;


3)Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485;


4)For high voltage DC 240V or 336V system, insulation monitoring module can be added to monitor ground insulation resistance of main bus;


5)DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output );


6)Communication: monitoring device by RS485, touch screen by RS485 or RJ45;


7)  Certificate:CE.


Human Machine Interface

IDC Precision Distribution Monitoring Solution
IDC Precision Distribution Monitoring Solution
IDC Precision Distribution Monitoring Solution
Setting Current Amarm

Main


Cabinet diagram

IDC Precision Distribution Monitoring Solution


Product Selection

Product Name

Product Image

Functions

AMC16Z-ZA Data Center Monitor Device

AMC16Z-ZA Data Center Monitor Device

● Designed specifically for the power supply management of server in the data center

● A+B independent 2 channels three-phase inlet

● U, I, P, Q, S, PF, kWh, kvarh

● 2nd-63rd  Harmonic

AMC16Z-FAK48 Data Center Monitor Device

AMC16Z-FAK48 Data Center Monitor Device

● Designed specifically for the power supply management of server in the data center

● A+B independent 24 circuits(48 in total)

● U, I, P, Q, S, PF, kWh, kvarh

● 2nd-31st  Harmonic

● kWh Class 0.5

● DIN 35 mm

AMC16Z-ZD DC Incoming Line Monitoring Module

AMC16Z-FAK48 Data Center Monitor Device

● DIN 35mm

● Measurement: A+B independent circuits, 6DI 2DO,1 temp. and humidity.

● With DC 24V output power supply for outgoing line module and touch screen.

● Communication:RS485 modbus RTU

AMC16Z-FDK24/48 DC Outgoing Line Monitoring Module


AMC16Z-FDK2448 DC Outgoing Line Monitoring Module

● DIN 35mm

● Can measure up to 48 circuits DC outgoing line

● DC24V power supply

● Communication:RS485 modbus RTU

AMC16Z-ZJY DC Incoming Line Insulation Monitoring Module


AMC16Z-ZJY DC Incoming Line Insulation Monitoring Module

● DIN 35mm

● Measure A+B independent DC circuit ground insulation resistance of main bus

● DC24V power supply

● Communication:RS485 modbus RTU

AMC16Z-FJY DC Outgoing Line Insulation Monitoring Module


AMC16Z-FJY DC Outgoing Line Insulation Monitoring Module

● DIN 35mm

● Measure 24 circuits ground insulation resistance of DC outgoing line

AKH-0.66/W Current Sensor


AKH-0.66W Current Sensor

● Current ratio:100A/50mA


● Common Specification: 100A/50mA

AHKC-BS DC Outgoing Line Hall Effect Current Sensor


AHKC-BS DC Outgoing Line Hall Effect Current Sensor

● Current ratio:100A/5V


● Common Specification: 100A/5V

ATP007kt ATP010kt HMI


ATP007kt ATP010kt HMI

● 7 or 10 inch touch screen


● Real-time monitoring and display voltage,current,power,energy,power quality,switch status,wave curve,etc. of the busbar


● Monitoring device alarm,communication and other parameters can be configured on the screen.


● 2 RS485 and 1 Ethernet,and data can uploaded by RS485 or RJ45


Photos on site

IDC Precision Distribution Monitoring Solution
IDC Precision Distribution Monitoring Solution
IDC Precision Distribution Monitoring Solution


Hot Products

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send