AcreIEMS-Zone Industrial Park Energy Management Solution
2024-02-01 11:58:54
New Generation Data Centres
Equipment Intelligence & Modularity
Virtulisation Everywhere
Unattended Remote Management
Green Energy Saving Everywhere
High Utilization of Equipment Resources
Redundant Design for High Availability
Industry Pain Points
Abnormal Power Failure
According to relevant industry experts, data centre downtime costs an average of nearly $8,000 per minute in the U.S. With Interxion's outage, the loss was over $9 million.
Large Volume of Energy Consumption and High Proportion of Carbon Emissions
Data centre operation uses large amounts of electricity and energy, requiring the industry to have a significant improvement in the efficiency of electricity use and renewable energy utilization, and the average electricity use efficiency of newly built large-scale and ultra-large-scale data centres should be reduced.
Energy Consumption Limits, Stringent PUE Energy Efficiency Requirements
Promote green upgrading of energy efficiency in key areas of data centres; specify industry PUE values.
Redundant Monitoring Sub-systems
Sub-systems such as integrated self, power monitoring, dynamic ring monitoring, intelligent lighting, video access control, fire monitoring and so on are many, dispersed and independent, with no interoperability of information and no interaction of sub-systems;
Numerous software (more than one APP), difficult maintenance (software, servers, application environments), high cost of learning, users can't get a complete understanding of the power supply, distribution and electricity consumption of the whole data centre through one set of system;
A large number of collection devices, networking devices and cabling are deployed repeatedly and cannot be shared, and similar functional modules such as system management, report reporting and alarm informing are duplicated, so the workload of modifying the configuration rises exponentially.
Industry Demand
Reliable & Safe
Reliable, stable and safe power supply and distribution.
Economical
Improve operation and maintenance efficiency, reduce operating costs.
Orderly
Integrated converged monitoring platform.
Low-carbon
Green low-carbon, save energy, reduce energy consumption, improve PUE.
Comprehensive
Multi-functionality.
High Efficiency
Best way to get things done with limited time and resources.
AcrelEMS-Zone System Functions
Power Monitoring
• Five Remote--Telemetry/Telecommunication/Remote Control/Telemodulation/Remote Viewing
• Page Configuration - Distribution Main Wiring Diagrams
• Curve Analysis
• Electricity centralised copying
• Optical Signage
• SOE Event
• Fault Recording
• Incident Memory
• Extreme value statistics
• DC Screen Monitoring
• Generator Monitoring
• Reactive power compensation cabinet monitoring
• Transformer monitoring
Power Quality Monitoring and Governance
• Steady state monitoring
• Steady state curve
• Harmonic Spectrum
• Harmonic curve
• Load curve
• Transient Analysis
• SOE Events
• Extreme value statistics
• Power Quality Analysis
• Power Quality Management
Electrical Safety
• Leakage monitoring
• Electrical contact temperature measurement
• Electrical Fire Monitoring
• Fire equipment power monitoring
• Fire Door Monitoring
• Emergency lighting and evacuation instructions
Intelligent Lighting
• Intelligent Lighting Control
• Control Events
• Lighting Control
• Scene Control
• Operation logging
• Timed Tasks
Energy Consumption Analysis
• Energy Consumption Statistics
• Energy consumption discount statistics
• Analysis of Energy Consumption
• Energy Consumption Trend Analysis
• Energy Flow Chart
Charging Post
• Real-time monitoring
• Transaction Management
• Fault Management
• Statistical Analysis
• Report Analysis
• Orderly Charging
Prepayment
• Real-time monitoring
• Account cancellation record
• Meter Return Record
• Meter Batch Operation
• Financial Statement
Operations and Maintenance Management
• Equipment Definition
• Equipment Archives
• Equipment Maintenance
• Maintenance Orders
• Inspection
• User Reports
Distributed Photovoltaic
• Power Station Operation Monitoring
• Inverter Operation Monitoring
• Power Station Generation Statistics
• Inverter power statistics
• PV Plant Distribution Diagram
• Inverter curve analysis
Industry Solutions for Industrial Zone/Industrial Park
APPLICATION
• Connection between low voltage cabinet
• Incoming line system at voltage transformer connection
• Power Distribution
• Power Supply
• Device with big current
APPLICATION
• Data Centre
• Tower Base Station
• Petroleum&Petrochemicals
• Traffic Industry
APPLICATION
• Data Centre
• Landscape Lighting
• Bridge
• Sports Stadium
• Office and Commercial Building
• Hotel
• Hospital
• Exhibition Venue
• Factory
• Transportation Station and Metro
• Campus
• Residential Community
• Logistics Centre
• Airport
• Shopping Mall
APPLICATION
• State Grid
• Municipal Engineering
• Traffic Industry
• Petroleum
• Data Centre
• Chemical Industry
• Industrial and Mining Industry
• Metallurgical Industry
APPLICATION
• Office and Commercial building
• Communication and Transportation building
• Data centre
• Scientific Educational Cultural and Healthy Architecture
APPLICATION
• Backflow prevention/Reflux
• Energy storage
• Bidirectional energy metering
APPLICATION
• AC and DC charging piles
APPLICATION
• AC and DC charging piles