0102030405
01
BM100-DI Series Current Input Analog Signal Isolator
2024-11-13
- Input 4~20mA/0~20mA DC,Distribution voltage ≥14V/20mA
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
01
BD-AI AC Current Transducer(1-phase 2-wire)
2024-05-23
- Measurement 1-phase AC Current
- Accuracy Class 0.5
- Input 0~1A AC/0~5A AC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
- Wiring 1-phase 2-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-DV Series DC Voltage Transducer
2024-11-14
- Measurement 1-phase DC Voltage
- Accuracy Class 0.5
- Input 0~75mV/0~10V/0~300V DC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
- Wiring 1-phase 2-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-DI Series DC Current Transducer
2024-11-14
- Measurement 1-phase DC Current
- Accuracy Class 0.5
- Input 4~20mA/0~20mA DC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
- Wiring 1-phase 2-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-AV Series Single Phase AC Voltage Transducer
2024-11-14
- Measurement 1-phase AC Voltage
- Accuracy Class 0.5
- Input 0~120V/0~300V/0~500V AC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
- Wiring 1-phase 2-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-3(4)V3 3P3W 3P4W AC Voltage Transducer
2024-11-14
- Measurement 3-phase AC Voltage
- Accuracy Class 0.5
- Input 0~120V/0~300V/0~500V AC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
- Wiring 3-phase 3-wire,3-phase 4-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-3(4)P/Q/I 3P3W 3P4W PQ Combination Transducer
2024-11-14
- Measurement 3-phase AC Active&Reactive Power (Range: -866~+866W)
- Accuracy Class 0.5
- Input 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
- Wiring 3-phase 3-wire,3-phase 4-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BD-3(4)P 3P3W 3P4W Reactive Power Transducer
2024-11-14
- Measurement 3-phase AC Active Power (Range: 0~+866W)
- Accuracy Class 0.5
- Input 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
- Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
- Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
- Wiring 3-phase 3-wire,3-phase 4-wire
- Applicaiton Paired with PLC for Industrial Automation; Used for Metering
- Response Time ≤400ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE
Inquiry
view
detail
01
BA50L-AI 0-1A Leakage Current Transducer
2024-11-14
- Input 0~(0.1~1)A AC
- Output 4~20mAV/0~20mA DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ50mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
01
BA50L(II)-AI 0-1A Split Type Leakage Current Transducer
2024-11-14
- Aperture 50mm
- Input 0~(0.1-1)A current
- Output DC 4-20mA or DC 0-5V, 0-10V
- Overload 1.2 times of rated value
- Power supply DC12V/DC24V
Inquiry
view
detail
01
BA50-AI 0-600A AC Current Transducer
2024-11-14
- Input 0~(60~600)A AC
- Output 1~5V/0~5V DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ50mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
01
BA50(II)-AI 0-600A Split Type Current Transducer
2024-11-14
- Aperture 50mm
- Input 0~(60-600A) current
- Output DC 4-20mA or DC 0-5V, 0-10V
- Overload 1.2 times of rated value
- Power supply DC12V/DC24V
Inquiry
view
detail
01
BA20-AI 0-200A AC Current Transducer
2024-11-14
- Input 0~(40~200)A AC
- Output 4~20mA/0~20mA DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ20mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
01
BA20(II)-AI 0-200A Split Type AC Current Transducer
2024-11-14
- Aperture 20mm
- Input 0~(0.5-200)A current
- Output DC 4-20mA or DC 0-5V, 0-10V
- Overload 1.2 times of rated value
- Power supply DC12V/DC24V
Inquiry
view
detail
01
BA05-AI 0-10A AC Current Transducer
2024-11-14
- Input 0~(0.5~10)A AC
- Output 4~20mA/0~20mA DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ5mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail