0102030405
01
BM200-VR Series Potentiometer Input Isolated Barrier
2024-11-13
- Input 0-10KΩ(Minimum Monitoring Range 1KΩ,Support 2-Wire 3-Wire)
- Output 4~20mA/0~20mA DC or 0~5V/0~10V/1~5V/2~10V
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
02
BM200-TR Series Thermal Resistance Input Isolated Barrier
2024-11-13
- Input Pt100: -200℃~850℃(minimum range 50℃),0~10KΩ(minimum range 1KΩ)
- Output 0~20mA /4~20mA (safe side output); Load resistance: ≤550Ω,0~5V/0~10V/1~5V/2~10V (safe side output); Load resistance: ≥30KΩ
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
03
BM200-DV Series Current Input Isolated Barrier
2024-11-13
- Input DC 0-5V/1-5V/0-10V/2-10V,Distribution voltage ≥10V/20mA
- Output 4~20mA/0~20mA/0-5V/1-5V/0-10V/2-10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
04
BM200-DI Series Current Input Isolated Barrier
2024-11-13
- Input 4~20mA/0~20mA DC,Distribution voltage ≥14V/20mA
- Output 4~20mA/0~20mA DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
05
BM100-VR Series Potentiometer Input Analog Signal Isolator
2024-11-13
- Input 0-10KΩ(maximum monitoring range is 1KΩ,support 2-Wire/3-Wire
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
06
BM100-TR Series Thermal Resistance Input Analog Signal Isolator
2024-11-13
- Input PT100(maximum 50℃,support 2-Wire and 3-Wire)
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
07
BM100-DV Series Voltage Input Analog Signal Isolator
2024-11-13
- Input 0~5V/1~5V/0~10V/2~10V DC
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V OR AC/DC 85~265V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
08
AHLC Series DC Leakage Hall Effect Sensor
2024-11-09
- Input DC 0~(10mA~2A)
- Output ±5V
- Power supply DC±15V
- Internal Dimension Φ 20 / 40 / 60mm
Inquiry
view
detail
09
AHKC-HB Open-loop Hall Effect Sensor (Split-core)
2024-11-08
- Input 0~±(400-20000)A
- Output ±5V/±4V
- Power supply DC ±15V
- Internal Dimension 120 * 51mm
Inquiry
view
detail
10
AHKC-EKC Open-loop Hall Effect Sensor (Split-core)
2024-11-08
- Rated Input 0~±1500A DC or 0~1500A AC
- Rated Output 0~±5/±4Vdc
- Aperture φ55mm
- Power Supply ±12~±15Vdc
- Accuracy Class 1.0
- Response Time ≤5us
- Installation Clamp on (Split-core) measuring cable and screw fixed on panel
- Standard&Certificate CE; IEC; LVD
Inquiry
view
detail
11
AHKC-EKB Open-loop Hall Effect Sensor (Split-core)
2024-11-08
- Rated Input 0~±1000A DC or 0~1000A AC
- Rated Output 0~±5/±4Vdc
- Aperture φ40mm
- Power Supply ±12~±15Vdc
- Accuracy Class 1.0
- Response Time ≤5us
- Installation Clamp on (Split-core) measuring cable and screw fixed on panel
- Standard&Certificate CE; IEC; LVD
Inquiry
view
detail
12
AHKC-E Closed-loop Hall Effect Sensor
2024-11-08
- Input AC/DC 0~500A
- Output DC ±5V/±4V
- Power supply DC ±15V
- Internal Dimension φ20mm
Inquiry
view
detail
13
AHKC-BSA Closed-loop Hall Effect Sensor
2024-11-08
● Input: AC/DC 0~500A
● Output:...
Inquiry
view
detail
14
AHBC-LTA Closed-loop Hall Effect Sensor
2024-11-08
● Input: AC/DC 100~300A
● Outpu...
Inquiry
view
detail
15
AKH-0.66/L Type Leakage Current Transformer
2024-11-08
● Round-hole type
● Square-hole...
Inquiry
view
detail