Precision Distribution Monitoring Solution for IDC
Overview
Applicaiton Scenarios
• Power monitoring at the end of Data Centre
• Multi channel power distribution box of the floor
• UPS Lead-acid Battery
Main Functions
• Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy and power quality
• Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485
• For high voltage DC 240V or 336V system, insulation monitoring module can be added to monitor ground insulation resistance of main bus
• DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output )
• Communication: monitoring device by RS485, touch screen by RS485 or RJ45 • Certificate:CE
Main Functions
• Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy and power quality
• Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485
• For high voltage DC 240V or 336V system, insulation monitoring module can be added to monitor ground insulation resistance of main bus
• DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output )
• Communication: monitoring device by RS485, touch screen by RS485 or RJ45 • Certificate:CE
Product Selection
AC-Inlet Module
AMC100-ZA
AC-Outlet Module
AMC100-FAK48 & FAK30
DC-Inlet Module
AMC100-ZD
DC-Outlet Module
AMC100-FDK48 & FDK30
Type |
Model |
Functions |
AC |
AMC100-ZA |
Monitor the fulll parameters of the A+B dual three-phase AC inlets, 8DI4DO, 2 inlets leakage monitoring, 1-way temperature and humidity, 2-63rd harmonic, 3-way RS485 communication (2-way up and 1-way down). |
AMC100-FAK30 |
Monitor the full parameters and switch(active), total current harmonic of a total of 30 outlets of AC A+B double-sided and 1 RS485 communication. |
|
AMC100-FAK48 |
Monitor the full parameters and switch(active), total current harmonics of a total of 48 outlets of AC A+B double-sided and 1 RS485 communication . |
|
AMC100-FA30 |
Monitor the full parameters of a total of 30 outlets of AC A+B double-sided and 1 RS485 communication. |
|
AMC100-FA48 |
Monitor the full parameters of a total of 30 outlets of AC A+B double-sided and 1 RS485 communication . |
|
DC -48V 240V 336V |
AMC100-ZD |
Monitor the fulll parameters of the A+B dual three-phase DC inlets, 8DI4DO, 2 inlets leakage monitoring, 1-way temperature and humidity, 3-way RS485 communication (2-way up and 1-way down). |
AMC100-FDK30 |
Monitor the full parameters and switch(active) of a total of 30 outlets of DC A+B double-sided and 1 RS485 communication. |
|
AMC100-FDK48 |
Monitor the full parameters and switch(active) of a total of 48 outlets of DC A+B double-sided and 1 RS485 communication . |
|
AMC100-FD30 |
Monitor the full parameters of a total of 30 outlets of DC A+B double-sided and 1 RS485 communication. |
|
AMC100-FD48 |
Monitor the full parameters of a total of 48 outlets of DC A+B double-sided and 1 RS485 communication. |
|
Switch |
AMC100-KA30 |
Monitor the switch(active) of a total of 30 outlets of DC A+B double-sided and 1 RS485 communication. |
AMC100-KA48 |
Monitor the switch(active) of a total of 48 outlets of DC A+B double-sided and 1 RS485 communication. |
|
AMC100-KD30 |
Monitor the switch(passive) of a total of 30 outlets of DC A+B double-sided and 1 RS485 communication. |
|
AMC100-KD48 |
Monitor the switch(passive) of a total of 48 outlets of DC A+B double-sided and 1 RS485 communication. |
|
Temperature |
AMC100-FT30 |
30 outlets NTC temperature measurement and 1 RS485 communication |
AMC100-FT48 |
48 outlets NTC temperature measurement and 1 RS485 communication |
• Matching transformer
Type |
Model |
Picture |
Screw fixation with plug |
AKH-0.66-9N-HB |
|
Guide rail type(spacing18/27mm) |
AKH-0.66-W-9A |
|
Guide rail type(Perforation free) |
AKH-0.66-EMS |
|
• Matching Hall Sensor
Type |
Model |
Picture |
DC Outlet HALL |
AHKC-BS-N |
|