Substation Automation Monitoring Solution

Overview

In order to assist users in achieving safe operation and comprehensive management of power transformation, distribution, and consumption in user substations (usually with voltage level of 35kV and below), Acrel provides:
Wireless Temperature Monitoring System
APD series UHF Partial Discharge Detector
Medium Voltage Protection relay
Power Quality Monitor Device
Arc Flash Protection Relay
The monitoring scope includes substation, switching station and low-voltage distribution room.

Applicaiton Scenarios

Data Center
Airport
Petrochemical
Steel Coal Mine
Machine Made
Industrial Park
Biopharmaceutical
Highway
Water Conservancy And Water Affairs
Steel Coal Mine
Achitechive
New Energy

Structure

变电站bs9

Rated Products

Wireless Temperature Monitoring System

图片49zr
ATE/NTC/PT100 Temperature Sensors
ATC/ASD/ARTM/ATP Temperature Receivers/Displays
Acrel-2000T series Acrel-2000T series

APD series UHF Partial Discharge Detector

Overview

Partial discharge phenomenon in switchgear:
Partial discharge in electrical equipment is accompanied by a series of factors such as electricity, light, sound, and heat The occurrence of physical phenomena, therefore, the partial discharge monitoring methods for high-voltage switchgear are all based on detecting these Physical quantities that can reflect the phenomenon of partial discharge are expanded.

The insulation strength and breakdown field strength of power equipment insulators are very high, when partial discharge is very smallWhen it occurs within the range of, the breakdown process will be rapid and there will be a rising edge during the breakdown processSteep partial discharge pulse current with a rise time of ns level and an excitation frequency of up to several GHzElectromagnetic wave signal of. Therefore, ultra-high frequency sensors can be used to monitor the internal partial discharge current of electrical equipmentThe excited electromagnetic wave signal evaluates the partial discharge situation of the switchgear.

Products

图片19f63

UHF sensor

Bandwidth:300MHz~1600MHz Effective

height:≥10.5mm

Interface:SMA

Connecting  cables:Coaxial cable

Protective class:IP65

Installation:Magnetic

图片17umt 

APD100 UHF Partial Discharge Detector

Power supply:DC10~30V,≤3W

Number of channels:One

Measuring range:-60dBm~+10dBm

Measurement content:Discharge amplitude and frequency

Connecting cables:Coaxial cable;

Matching impedance:50Ω

Relay output:1 circuit normally open relay,5A/AC250V,5A/DC30V

Communication interface:RS485 * 1、Lora * 1

Installation:35mm guide rail installation

图片18stl  

APD200 UHF Partial Discharge Detector

Power supply:AC/DC220V,≤3W

Number of channels:One

Measuring range:-60dBm~+10dBm

Measurement content:Discharge amplitude and frequency

PRPD, PRPS

Phase synchronization:Internal synchronization (AC power)

Discharge type recognition:Free metal particle discharge, suspended potential discharge, insulation air gap discharge/pollution discharge, corona discharge

Connecting cables:Coaxial cable

Matching impedance:50Ω

Communication protocol:RS485 * 1、USB-C * 1

Relay output:1 circuit normally open relay;5A/AC250V,5A/DC30V

Installation:35mm guide rail installation

System Networking

Power monitor system 2024lzm

Medium Voltage Protection relay

Overview

When a severe fault(such as short circuit) occurs within the power system that threatens the operation of the system, the device can quickly and correctly cut off the fault circuit or electrical equipment to limit the expansion of the accident and ensure the normal operatin of other parts;

When abnormal operation mode occurs within the system, the device can automatically send a warning signal to inform the personnel on duty to deal with it

Function

Make sure the power system can effectively deal with the faults and minimize losses

Protection relays are generally classified by the protected objects. The common protection devices on users’side projects include main transformer protection, circuit protection, transformer protection, motor protection, PT protection, busbar protection, capacitor protection, standby automatic switching protection, etc.
图片5wn8

Resource comparison

背面 AM5SE6fn

AM5SE

back-amy7w

AM5SE

背面 AM2SEmfv

AM5SE

Properties

AM5SE

AM3SE

AM2SE

Power Collection

Protection Current

3 circuits

3 circuits

3 circuits

Measurement Current

3 circuits

N/A

N/A

Zero-sequence Current

2 circuits

2 circuits

1 circuit

Bus Voltage

3 circuits+spare 2 circuits

3 circuits

3 circuits

Zero-sequence Voltage

1 circuit

4-20mA Output

2 circuits optional

N/A

N/A

DC Current Measurement

N/A

N/A

N/A

Input and Output

DI

20 circuits

11 circuits

8 circuits

DO

10 circuits

5 circuits

5 circuits

Communication

RS485 Communication Interface

2 circuits

1 circuit

1 circuit

RS232 Maintenance Interface

1

N/A

N/A

IRIG-B Timing Interface

A

A

N/A

USB Upgrade Interface

A

N/A

N/A

RJ45 Network Interface

2 circuits optional

N/A

N/A

Operation Circuit

Operation Circuit

A

N/A

N/A

Anti-trip Function

Built-in

Anti-trip module optional

    
Anti-trip module optional

Resource comparison

Product selection points:
1.Use cabinet type according to the project;
2.According to the project application scenario;
3.According to the project protection function requirements;
4.Comprehensive consideration of project cost.

Protecition Function

AM5SE

AM3SE

AM2SE

 Main transformer differential protection

×

×

Main transformer backup protection

×

×

Three-stage overcurrent with direction and voltage lockout

×

×

Three-stage overcurrent

--

Zero-sequence overcurrent

Over-voltage, low-voltage protection

High-power motor differential protection (>2000kW)

×

×

High-voltage motor integrated protection

×

×

High voltage single bus system incoming line/bus coupler backup automatic switching function

×

×

PT parallel function

×

×

Non-electricity protection (temperature, gas)

Grid connection reverse power protection

×

×

Check synchronization function

×

×

Electrical parameter measurement function

U,I,f,P,Q,PF,Ep,Eq,Es

Solution

• Ring main unit protection scheme

图片6uop
AM2SE Protection relay

Applicable scenario

Installation method

Main function

10kV/6kVResidential projects,construction projects(commercial, hotel, municipal, etc.), etc

Embedded installation, snap fixing.

[50/51]Three-stage overcurrent ;
[50N/51N]Zero-sequence overcurrent protection  (3 stages earth fault);
[59]Overvoltage protection ;
[27]Under voltage protection
[81U]Under frequency ;
[26/63]Non-electricity Protection ;
Electrical parameter measurement: U,I,f,P,Q,PF,Ep,Eq,Es

Installation construction
图片22snq

Main view

图片23h5g

Slide view

图片243yr

Hole size

AM2SE Protection relay diagram
图片8gmi

• Central cabinet protection scheme

图片9dav
AM3SE Protection relay

Applicable scenario

Installation method

Main function

Municipal construction, hospitals, schools, hotels, commercial buildings, etc.

 Embedded installation, snap fixing

[50/51] Overcurrent , 3stages;
[50N/51N]Zero-sequence overcurrent protection (3 stages earth fault);
[59] Over voltage protection;
[27] Under voltage protection;
[81U] Under frequency;
[26/63] Non-electricity protection;
[79] Auto-reclose;
Electrical parameter measurement :U,I,f,P,Q,PF,Ep,Eq,Es

Installation construction
图片28iha

Main view

picturez5x

Slide view

图片30jkm

Hole size

AM3SE Protection relay diagram case example
图片104ce
AM5SE Protection relay

Applicable scenario

Installation method

Main function

35kV substation, industrial and mining enterprises, power plants, new energy power generation and other fields

 Embedded installation, snap fixing

[67] Overcurrent , 3stages (with direction and voltage lockout);
  [50N/51N] Zero-sequence overcurrent protection (2 stages earth fault);
  [59] Over voltage protection;
  [27] Under voltage protection;
  [26/63] Non-electricity protection;
  [25] Check synchronization;
  [32R] Directional power protection;
  [ATS] Bus tie protection;
  [87T] Transformer differential protection of main transformer;
  Main transformer backup protection;
  Motor protection;
  [87M] Motor differential protection;
  Capacitor protection protection;
  [VTS] PT supervision and parallel connection;

图片11m2z
AM5SE Protection relay
图片33j2t

• Other protection scheme

Application

Model

Incoming line protection —— Line protection device

AM5SE-F

AM3SE-I

AM2SE

 

Protect the distribution transformer (Capacity less than 2000kVA) —— Transformer protection replay

AM5SE-T

AM3SE-I

AM2SE

 

Protect the main transformer (Capacity greater than 2000kVA) ——
Main transformer differential + Main transformer backup protection replay

Main functions of AM5SE-D2 (main transformer differential)

Main functions of AM5SE-TB (main transformer backup)

Protect the motor (power less than 2000kW) —— Motor protection replay

AM5SE-M

 

Protect the motor (power greater than 2000kW) —— Motor differential protection relay

AM5SE-MD

 

Protect the capacitor —— Capacitor protection replay

AM5SE-C

Automatic switching protection of standby power supply —— backup automatic switch protection replay

AM5SE-B

 

Automatic switching protection of standby power supply —— backup automatic switch protection replay

AM5SE-IS

Power Quality Monitor Device

图片33j2t

APView500
Online monitoring device for power quality

Product Description

The digital universal measuring device APView500 is suited for measuring and displaying electrical quantities of electricity networks. The device measures currents, voltages and power, and displays the individual current/voltage harmonics for assessment of the power quality.

Typical Application

Continuous monitoring of the voltage quality
Collection of relevant data for energy management systems
Collection of relevant data for energy management systems

Device Features

Monitoring the quality of the voltage
TFT colour display (800×480) 5.0
Modbus RTU,Modbus TCP,IEC 61850
8 current inputs
8 voltage inputs
32 GB internal memory
Flicker measurement
Sampling rate: 1024 samples/cycle
Statistical data recorder 90 days @ 1-minute PQDIF file format
Downloadable from the on-board FTP Server.
Waveform recordings are in COMTRADE file format,downloadable from the on-board Web Server of FTP Server

Device Features

Sampling rate of the measuring channels: 51.2 kHz
Power Frequency
Magnitude of the Supply Voltage and Current
Flicker
Transients, Dips/Swells and Interruptions
Supply Voltage Unbalance and Current Unbalance
Flicker measurement
Sampling rate: 1024 samples/cycle
Measurement of Over and Under Deviation parameters
Harmonics and Interharmonics Measurements for Voltage and Current
Communication:
–Galvanically isolated RS-485 interface,Ethernet interface
–Modbus RTU protocol
–Modbus TCP (10/100 MBit/s)

Monitor Function

• Steady state monitoring

Measurement of voltage, current, power, energy, etc
Deviation
Voltage imbalance/current imbalance
Harmonic voltage/harmonic current
Harmonic voltage/inter harmonic current
Harmonic power/harmonic phase angle/harmonic distortion rate
High-frequency harmonics
Voltage Fluctuation and Flicker
Rapid voltage change
图片12buh

• Transient monitoring

Swells
Temporary descent
Short interruption
Temporary drop source positioning
Tolerance curve analysis
Short term interruption: The phenomenon where the root mean square value of the power frequency voltage at a certain point in the power system suddenly drops below 0.1 p.u. and returns to normal after a brief duration of 10ms to 1 min
Voltage sag: The phenomenon where the root mean square value of the power frequency voltage at a certain point in the power system suddenly decreases to 0.1 p.u.~0.9 p.u. and returns to normal after a brief duration of 10ms to 1 min.
图片13cj6
图片148mg
图片157yn

• Fault waveform

COMTRADE is a data file format suitable for obtaining transient waveforms and events in power system models
Deviation
Frequency deviation
Voltage swell
Voltage sag
Short time interruption of voltage
Voltage transient
图片16z0g
图片17y9l

• Record storage

PQDIF format file, compressed file for steady-state data within 2 hours.
PQDIF data storage
Data export
Saving event records
图片18x5v

The storage chip has a capacity of 32G and can save real-time monitoring point data. The 1-minute data (including mean, maximum, minimum, 95% probability maximum, and root mean square) can be stored on the device for a maximum of 3 months, and then updated according to the "first in, first out" principle. The PQDIF data type meets the requirements of DL/T 1608 Power Quality Data Exchange Format Specification, and PQDIF data should be able to be stored for 90 days; The PQDIF data and fault recording data recorded by the device can be saved locally through FTP.

Arc Flash Protection Relay

图片19qpn

Application

Industry Sector
Industry (coal mine/steel/petroleum/chemical/textile)
Water conservancy and water affairs
School, Education
Medical hygiene
Municipal and industrial parks
Transportation facilities (airports/train stations/highways)
Residential and Architectural
Data Center
power plant
Biopharmaceuticals
New energy
Semiconductor
Ships

Scheme Features

Used to protect medium and low voltage switchgear (busbar room, handcart room, cable room)

Advantages

Fast action time, more advantageous compared to traditional protection systems;
Adopting dual criteria of arc light and current overcurrent increases reliability and safety;
Being able to accurately locate the fault point can reduce the time for maintenance personnel to search for the fault point, greatly reducing maintenance time, and ensuring rapid restoration of power supply after accident maintenance.

Advantages

Model

Feature

Main Function

Performance Characteristics

图片50dcq 
ARB6 Arc Flash Protection Relay Relay

30 arc light probes connected

4 sets of three-phase current collection

3 sets of zero sequence voltage acquisition

4 programmable fast trip outlets

10 programmable trip outlets

2 programmable normally closed outlets

5/22 input channels

1-way USB

1 channel timing interface

2-way RS485

3-way Ethernet

 

Customize multiple groups of arc protection logic

Arc light fault location

Real time self inspection of arc probe and fiber optic link

Arc light action value can be freely adjusted

4 sets of failure protection

4 sets of non battery protection

CT disconnection alarm

4 sets of current circuit TA monitoring

Device fault alarm

Maintenance status locking

Supports Modbus RTU/Modbus TCP/IEC103

Each device can optionally collect 6/12/18/24/30 probes

The arc probe directly transmits optical signals to the arc protection device through plastic optical fibers

Single criterion action time 3.8ms, double criterion action time 7.8ms

High reliability, certified by national authoritative testing institutions

图片54yr2 
ARB5-M Main control unit

20 arc light probes connected

4 sets of three-phase current collection

11 pairs of programmable trip outlets

24 channel input

2-way RS485/2-way Ethernet/1-way

RS232 printing interface/1-way timing

interface

Customize multiple groups of arc protection logic

Arc light fault location

Real time self inspection of arc probe and fiber optic link

4 sets of failure protection

4 sets of current circuit TA monitoring

Non battery protection

Device fault alarm

The communication protocol supports Modbus RTU, Modbus TCP, and IEC103,

Communication protocol supports IEC61850 and GOOSE input and output (optional)

Arc light collection board, each equipped with 4 pieces, each piece can collect 5 arc light probes, a total of 20 probes

The arc probe directly transmits optical signals to the arc control unit through plastic optical fibers

图片51lm0 
Arc probe ARB-S

Equipped with light filtering function

Passive arc light sensor

Real time self inspection of probe and fiber optic link

Arc optical fiber: double stranded, flame retardant

No metal parts, no electrical safety hazards

 

Angle ≥ 180°

Radius ≥ 0.5m

Sensitivity type: visible light/ultraviolet light

 

 

Installation

图片20aoy

图片58do3 

图片593nr 

Busbar Compartment

Circuit Breaker Room

Cable Room