Substation Automation Monitoring Solution
Overview
● Wireless Temperature Monitoring System
● APD series UHF Partial Discharge Detector
● Medium Voltage Protection relay
● Power Quality Monitor Device
● Arc Flash Protection Relay
The monitoring scope includes substation, switching station and low-voltage distribution room.
Applicaiton Scenarios
● Airport
● Petrochemical
● Steel Coal Mine
● Machine Made
● Industrial Park
● Highway
● Water Conservancy And Water Affairs
● Steel Coal Mine
● Achitechive
● New Energy
Structure

Rated Products
Wireless Temperature Monitoring System

ATC/ASD/ARTM/ATP Temperature Receivers/Displays
Acrel-2000T series Acrel-2000T series
APD series UHF Partial Discharge Detector
Overview
● Partial discharge in electrical equipment is accompanied by a series of factors such as electricity, light, sound, and heat The occurrence of physical phenomena, therefore, the partial discharge monitoring methods for high-voltage switchgear are all based on detecting these Physical quantities that can reflect the phenomenon of partial discharge are expanded.
● The insulation strength and breakdown field strength of power equipment insulators are very high, when partial discharge is very smallWhen it occurs within the range of, the breakdown process will be rapid and there will be a rising edge during the breakdown processSteep partial discharge pulse current with a rise time of ns level and an excitation frequency of up to several GHzElectromagnetic wave signal of. Therefore, ultra-high frequency sensors can be used to monitor the internal partial discharge current of electrical equipmentThe excited electromagnetic wave signal evaluates the partial discharge situation of the switchgear.
Products
UHF sensor |
● Bandwidth:300MHz~1600MHz Effective ● height:≥10.5mm ● Interface:SMA ● Connecting cables:Coaxial cable ● Protective class:IP65 ● Installation:Magnetic |
APD100 UHF Partial Discharge Detector |
● Power supply:DC10~30V,≤3W ● Number of channels:One ● Measuring range:-60dBm~+10dBm ● Measurement content:Discharge amplitude and frequency ● Connecting cables:Coaxial cable; ● Matching impedance:50Ω ● Relay output:1 circuit normally open relay,5A/AC250V,5A/DC30V ● Communication interface:RS485 * 1、Lora * 1 ● Installation:35mm guide rail installation |
APD200 UHF Partial Discharge Detector |
● Power supply:AC/DC220V,≤3W ● Number of channels:One ● Measuring range:-60dBm~+10dBm ● Measurement content:Discharge amplitude and frequency ● PRPD, PRPS ● Phase synchronization:Internal synchronization (AC power) ● Discharge type recognition:Free metal particle discharge, suspended potential discharge, insulation air gap discharge/pollution discharge, corona discharge ● Connecting cables:Coaxial cable ● Matching impedance:50Ω ● Communication protocol:RS485 * 1、USB-C * 1 ● Relay output:1 circuit normally open relay;5A/AC250V,5A/DC30V ● Installation:35mm guide rail installation |
System Networking

Medium Voltage Protection relay
Overview
When abnormal operation mode occurs within the system, the device can automatically send a warning signal to inform the personnel on duty to deal with it
Function
Protection relays are generally classified by the protected objects. The common protection devices on users’side projects include main transformer protection, circuit protection, transformer protection, motor protection, PT protection, busbar protection, capacitor protection, standby automatic switching protection, etc.

Resource comparison

AM5SE

AM5SE

AM5SE
|
Properties |
AM5SE |
AM3SE |
AM2SE |
Power Collection |
Protection Current |
3 circuits |
3 circuits |
3 circuits |
Measurement Current |
3 circuits |
N/A |
N/A |
|
Zero-sequence Current |
2 circuits |
2 circuits |
1 circuit |
|
Bus Voltage |
3 circuits+spare 2 circuits |
3 circuits |
3 circuits |
|
Zero-sequence Voltage |
1 circuit |
|||
4-20mA Output |
2 circuits optional |
N/A |
N/A |
|
DC Current Measurement |
N/A |
N/A |
N/A |
|
Input and Output |
DI |
20 circuits |
11 circuits |
8 circuits |
DO |
10 circuits |
5 circuits |
5 circuits |
|
Communication |
RS485 Communication Interface |
2 circuits |
1 circuit |
1 circuit |
RS232 Maintenance Interface |
1 |
N/A |
N/A |
|
IRIG-B Timing Interface |
A |
A |
N/A |
|
USB Upgrade Interface |
A |
N/A |
N/A |
|
RJ45 Network Interface |
2 circuits optional |
N/A |
N/A |
|
Operation Circuit |
Operation Circuit |
A |
N/A |
N/A |
Anti-trip Function |
Built-in |
Anti-trip module optional |
|
Resource comparison
1.Use cabinet type according to the project;
2.According to the project application scenario;
3.According to the project protection function requirements;
4.Comprehensive consideration of project cost.
Protecition Function |
AM5SE |
AM3SE |
AM2SE |
Main transformer differential protection |
√ |
× |
× |
Main transformer backup protection |
√ |
× |
× |
Three-stage overcurrent with direction and voltage lockout |
√ |
× |
× |
Three-stage overcurrent |
-- |
√ |
√ |
Zero-sequence overcurrent |
√ |
√ |
√ |
Over-voltage, low-voltage protection |
√ |
√ |
√ |
High-power motor differential protection (>2000kW) |
√ |
× |
× |
High-voltage motor integrated protection |
√ |
× |
× |
High voltage single bus system incoming line/bus coupler backup automatic switching function |
√ |
× |
× |
PT parallel function |
√ |
× |
× |
Non-electricity protection (temperature, gas) |
√ |
√ |
√ |
Grid connection reverse power protection |
√ |
× |
× |
Check synchronization function |
√ |
× |
× |
Electrical parameter measurement function |
U,I,f,P,Q,PF,Ep,Eq,Es |
Solution
• Ring main unit protection scheme

Applicable scenario |
Installation method |
Main function |
10kV/6kVResidential projects,construction projects(commercial, hotel, municipal, etc.), etc |
Embedded installation, snap fixing. |
[50/51]Three-stage overcurrent ; |

Main view

Slide view

Hole size

• Central cabinet protection scheme

Applicable scenario |
Installation method |
Main function |
Municipal construction, hospitals, schools, hotels, commercial buildings, etc. |
Embedded installation, snap fixing |
[50/51] Overcurrent , 3stages; |

Main view

Slide view

Hole size

Applicable scenario |
Installation method |
Main function |
35kV substation, industrial and mining enterprises, power plants, new energy power generation and other fields |
Embedded installation, snap fixing |
[67] Overcurrent , 3stages (with direction and voltage lockout); |


• Other protection scheme
Application |
Model |
Incoming line protection —— Line protection device |
● AM5SE-F ● AM3SE-I ● AM2SE
|
Protect the distribution transformer (Capacity less than 2000kVA) —— Transformer protection replay |
● AM5SE-T ● AM3SE-I ● AM2SE
|
Protect the main transformer (Capacity greater than 2000kVA) —— Main transformer differential + Main transformer backup protection replay |
● Main functions of AM5SE-D2 (main transformer differential) ● Main functions of AM5SE-TB (main transformer backup) |
Protect the motor (power less than 2000kW) —— Motor protection replay |
● AM5SE-M
|
Protect the motor (power greater than 2000kW) —— Motor differential protection relay | ● AM5SE-MD
|
Protect the capacitor —— Capacitor protection replay |
● AM5SE-C |
Automatic switching protection of standby power supply —— backup automatic switch protection replay |
● AM5SE-B
|
Automatic switching protection of standby power supply —— backup automatic switch protection replay |
● AM5SE-IS
|
Power Quality Monitor Device

APView500
Online monitoring device for power quality
Product Description
Typical Application
● Collection of relevant data for energy management systems
● Collection of relevant data for energy management systems
Device Features
● TFT colour display (800×480) 5.0
● Modbus RTU,Modbus TCP,IEC 61850
● 8 current inputs
● 8 voltage inputs
● 32 GB internal memory
● Flicker measurement
● Sampling rate: 1024 samples/cycle
● Statistical data recorder 90 days @ 1-minute PQDIF file format
● Downloadable from the on-board FTP Server.
● Waveform recordings are in COMTRADE file format,downloadable from the on-board Web Server of FTP Server
Device Features
● Power Frequency
● Magnitude of the Supply Voltage and Current
● Flicker
● Transients, Dips/Swells and Interruptions
● Supply Voltage Unbalance and Current Unbalance
● Flicker measurement
● Sampling rate: 1024 samples/cycle
● Measurement of Over and Under Deviation parameters
● Harmonics and Interharmonics Measurements for Voltage and Current
● Communication:
–Galvanically isolated RS-485 interface,Ethernet interface
–Modbus RTU protocol
–Modbus TCP (10/100 MBit/s)
Monitor Function
• Steady state monitoring
● Deviation
● Voltage imbalance/current imbalance
● Harmonic voltage/harmonic current
● Harmonic voltage/inter harmonic current
● Harmonic power/harmonic phase angle/harmonic distortion rate
● High-frequency harmonics
● Voltage Fluctuation and Flicker
● Rapid voltage change

• Transient monitoring
● Temporary descent
● Short interruption
● Temporary drop source positioning
● Tolerance curve analysis
Short term interruption: The phenomenon where the root mean square value of the power frequency voltage at a certain point in the power system suddenly drops below 0.1 p.u. and returns to normal after a brief duration of 10ms to 1 min
Voltage sag: The phenomenon where the root mean square value of the power frequency voltage at a certain point in the power system suddenly decreases to 0.1 p.u.~0.9 p.u. and returns to normal after a brief duration of 10ms to 1 min.



• Fault waveform
● Deviation
● Frequency deviation
● Voltage swell
● Voltage sag
● Short time interruption of voltage
● Voltage transient


• Record storage
● PQDIF data storage
● Data export
● Saving event records

Arc Flash Protection Relay

Application
● Industry (coal mine/steel/petroleum/chemical/textile)
● Water conservancy and water affairs
● School, Education
● Medical hygiene
● Municipal and industrial parks
● Transportation facilities (airports/train stations/highways)
● Residential and Architectural
● Data Center
● power plant
● Biopharmaceuticals
● New energy
● Semiconductor
● Ships
Scheme Features
Advantages
● Adopting dual criteria of arc light and current overcurrent increases reliability and safety;
● Being able to accurately locate the fault point can reduce the time for maintenance personnel to search for the fault point, greatly reducing maintenance time, and ensuring rapid restoration of power supply after accident maintenance.
Advantages
Model |
Feature |
Main Function |
Performance Characteristics |
|
● 30 arc light probes connected ● 4 sets of three-phase current collection ● 3 sets of zero sequence voltage acquisition ● 4 programmable fast trip outlets ● 10 programmable trip outlets ● 2 programmable normally closed outlets ● 5/22 input channels ● 1-way USB ● 1 channel timing interface ● 2-way RS485 ● 3-way Ethernet
|
● Customize multiple groups of arc protection logic ● Arc light fault location ● Real time self inspection of arc probe and fiber optic link ● Arc light action value can be freely adjusted ● 4 sets of failure protection ● 4 sets of non battery protection ● CT disconnection alarm ● 4 sets of current circuit TA monitoring ● Device fault alarm ● Maintenance status locking ● Supports Modbus RTU/Modbus TCP/IEC103 |
● Each device can optionally collect 6/12/18/24/30 probes ● The arc probe directly transmits optical signals to the arc protection device through plastic optical fibers ● Single criterion action time 3.8ms, double criterion action time 7.8ms ● High reliability, certified by national authoritative testing institutions |
|
● 20 arc light probes connected ● 4 sets of three-phase current collection ● 11 pairs of programmable trip outlets ● 24 channel input ● 2-way RS485/2-way Ethernet/1-way ● RS232 printing interface/1-way timing ● interface |
● Customize multiple groups of arc protection logic ● Arc light fault location ● Real time self inspection of arc probe and fiber optic link ● 4 sets of failure protection ● 4 sets of current circuit TA monitoring ● Non battery protection ● Device fault alarm ● The communication protocol supports Modbus RTU, Modbus TCP, and IEC103, ● Communication protocol supports IEC61850 and GOOSE input and output (optional) |
● Arc light collection board, each equipped with 4 pieces, each piece can collect 5 arc light probes, a total of 20 probes ● The arc probe directly transmits optical signals to the arc control unit through plastic optical fibers |
|
● Equipped with light filtering function ● Passive arc light sensor ● Real time self inspection of probe and fiber optic link ● Arc optical fiber: double stranded, flame retardant ● No metal parts, no electrical safety hazards |
● Angle ≥ 180° ● Radius ≥ 0.5m ● Sensitivity type: visible light/ultraviolet light
|
|
Installation
|
|
|
Busbar Compartment |
Circuit Breaker Room |
Cable Room |