English
Leave Your Message
655ddc4ece25e726951rx

Charging Pile Energy Management System Solution

Overview

In recent years, in response to global warming and climate change caused by greenhouse gas emissions,major countries have focused on promoting electric vehicles to replace traditional fuel vehicles. And the construction of charging piles is very important in the promotion of new energy vehicles. Therefore, a large number of charging pile projects have emerged around the world.
Single phase and three phase AC, DC energy meters complies with the corresponding IEC standards and can be used in all kinds of AC and DC charging piles to realize charging energy measurement, and can transmit electrical parameters in real time through communication.

Applicaiton Scenarios

• AC and DC Charging Piles
• AC and DC Charging Stations

Major Types of EV Charging Station and their requests for Energy Meter

Type 1: Small 1-phase AC EV Charging Station

- Noted: Request below are request of EV charging station to the energy meter used by it.

- Rated Voltage: Request rated voltage in the range of 220~ 264Vac L-N (1-phase)

- Rated Current: Request Max current at least 60A AC

- Communication: Request RS485 communication for

control function

- Metering: Request Multi-rate/tariff metering as a optional Function

1712056980858yn9

Type 2: Small 3-phase AC EV Charging Station

- Noted: Request below are request of EV charging station to the energy meter used by it.

- Rated Voltage: Request rated voltage in the range of 380~ 456Vac L-L & 220~264Vac L-N (3-phase)

- Rated Current: Request Max current input at least 80A AC (direct connect type) or Max 5A AC current input (via CTs)

- Communication: Request RS485 communication for

control function

- Metering: Request Multi-rate/tariff metering as a optional function

图片2bjm

Type 3: Medium&Large DC EV Charging Station

- Noted: Request below are request of EV charging station to the energy meter used by it.

- Rated Voltage: Request rated voltage in the range of 200~ 1000Vdc

- Rated Current: Request Max current input normally not

more that 500A DC

- Communication: Request RS485 communication for

control function

- Metering: Request Multi-rate/tariff metering as a optional function

1712056991154apg

Energy Meter Model Selection

Energy Meter Model Selection

Model 1: ADL200 1-phase DIN-rail Energy Meter

- Rated Voltage: 220~264Vac L-N (45~65Hz)

- Rated Current: 10(80)A AC

- Accuracy: Class 1.0 for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering & Pulse Output

- Certificate&Standard: IEC; CE; CE-MID;EAC

1712057001876xbd

Model 1: ADL200 1-phase DIN-rail Energy Meter

- Rated Voltage: 220~264Vac L-N (45~65Hz)

- Rated Current: 10(80)A AC

- Accuracy: Class 1.0 for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering & Pulse Output

- Certificate&Standard: IEC; CE; CE-MID;EAC

1712057001876xbd

Model 2: ADL10-E 1-phase DIN-rail Energy Meter

- Rated Voltage: 220~264Vac L-N (45~65Hz)

- Rated Current: 10(60)A AC

- Accuracy: Class 1.0 for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Certificate&Standard: CE; EAC

1712057014719hiy

For Small 3-phase AC EV Charging Station

Model 1: ADL400 3-phase DIN-rail Energy Meter

- Rated Voltage: 3x380~456Vac L-L & 220~264Vac L-N (45 ~65Hz)

- Rated Current: 3x10(80)A AC (direct connect) or 3x1(6)A AC (via CTs)

- Accuracy: Class 0.5S for active energy monitoring

- Harmonic: Total and 2~31st harmonic monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering & Pulse Output

- Certificate&Standard: IEC; CE; CE-MID;EAC

171205702315276p

Model 2: ADL3000-E 3-phase DIN-rail Energy Meter

- Rated Voltage: 3x380~456Vac L-L & 220~264Vac L-N (45 ~65Hz)

- Rated Current: 3x10(80)A AC (direct connect) or 3x1(6)A AC (via CTs)

- Accuracy: Class 0.5S for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Certificate&Standard: UL; CE; IEC; EAC

1712057030368a8g

For Medium-Large DC EV Charging Station

Model 1: DJSF1352-RN DC Din-rail Energy Meter

- Voltage Input Range: 0~1000Vdc

- Current Input Range: 0~5Vdc, 4~20mA DC (via Hall

Sensor) 0~75mV (via Shunt) and etc.

- Accuracy: Class 1.0 for active energy monitoring

-Communicaiton: RS485 Interface

, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering & Optional Dual

Circuits Monitoring

- Certificate&Standard: CE

MODBUS-RTU Protocol

- Certificate&Standard: UL; CE; IEC; EAC

1712057040721j0d

Model 2: PZ72L-DE DC Panel mounted Energy Meter

- Voltage Input Range: 0~1000Vdc

- Current Input Range: 0~5Vdc, 4~20mA DC (via Hall Sensor) 0~75mV (via Shunt) and etc.

- Accuracy: Class 1.0 for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering

- Certificate&Standard: CE 

1712057047009eeo

Model 2: PZ72L-DE DC Panel mounted Energy Meter

- Voltage Input Range: 0~1000Vdc

- Current Input Range: 0~5Vdc, 4~20mA DC (via Hall Sensor) 0~75mV (via Shunt) and etc.

- Accuracy: Class 1.0 for active energy monitoring

- Communicaiton: RS485 Interface, MODBUS-RTU Protocol

- Extra Function: Multi-rate/tariff metering

- Certificate&Standard: CE 

1712057054290sno

Shunt&Hall Sensor Model Selection

Shunt&Hall Sensor Model Selection

Model 1: AFL-T Series Shunt 

- Current Input Range: 0~(50~500)A DC 

- Current Output Range: 0~75mV 

- Advantage: High accuracy, strong anti-interference 

- Application: Paired with Acrel DC energy meter for current intput

图片1zdb

Model 2: AHKC-EKA Split-core Hall Sensor 

- Current Input Range: 0~(50~500)A DC 

- Current Output Range: 0~±5Vdc 

- Aperture: φ20mm 

- Auxiliary Power Supply: ±12~±15Vdc 

- Advantage: Safety with electricity isolation 

- Application: Paired with Acrel DC energy meter for current intput 

2uet

Model 2: AHKC-EKB Split-core Hall Sensor 

- Current Input Range: 0~(200~1000)A DC 

- Current Output Range: 0~±5Vdc 

- Aperture: φ40mm 

- Auxiliary Power Supply: ±12~±15Vdc 

- Advantage: Safety with electricity isolation 

- Application: Paired with Acrel DC energy meter for current intput 

3lbi

Projects