01

Three-phase AC Multi-function Panel Energy Meter AMC96L-E4/KC

2024-02-02
  • Measurement 3-phase AC kWh, kVarh, I, U, kW, kVar, Hz, cosφ and etc
  • Accuracy 1% (kWh); 0.5% (Active Power)
  • Rated Voltage 400V or 660V AC L-L (direct connect); 100V AC L-L (via PTs)
  • Rated Current 5A AC or 1A AC (via CTs)
  • Power Supply 85~265V AC/DC; 24V or 48V DC
  • Communication RS485 (MODBUS-RTU)
  • SOE Funciton Event&Demand&Extremum Record
  • Harmonic Measurement 2~31st and total Harmonic
  • Analog Output 4~20mA DC or 1~5V DC
  • DI/DO Function 2/4-channel DI&2-channel DO
  • Standard&Certificate CE Certificates
02

Acrel ATE400 Wireless Temperature Measuring Sensor

2024-05-23
  •  Range of Measurement  -50℃~+125℃
  • Communication  GFSK Wireless Communication
  • Application Switchgear, Busbar, Bus duct, Electric contact, Cable joint, Rain main unit and etc
  • Installation  Bolted, Magnetic, Belt, Alloy Sheet Fixed
  • Protection Level  IP68 (Optional)
  •  Power Supply Battery or CT Sensing Power
  •  Standard&Certificate  CE
03

BD-AI AC Current Transducer(1-phase 2-wire)

2024-05-23
  • Measurement 1-phase AC Current
  •  Accuracy Class 0.5
  • Input 0~1A AC/0~5A AC
  • Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)
  • Power Supply 85~265V AC(50Hz) or 100~350V DC or 24V DC
  • Wiring 1-phase 2-wire
  • Applicaiton Paired with PLC for Industrial Automation; Used for Metering
  • Response Time ≤400ms
  •  Installation 35mm DIN Rail/Screw fixed
  • Standard&Certificate CE
04

AHE100 Temperature Humidity Sensor

2024-04-28
  • Temperature measuring range '-45~85℃
  • Humidity measuring range 0~100%RH
  • Temperature accuracy ±1℃
  • Humidity accuracy ±2%RH
  • Acquisition frequency 25s
  • Transmitting frequency 5min(Report in advance if the temperature changes ≥2℃ or humidity changes ≥5%RH within 5 min)
  • Transmission distance 500m(empty space)
  • Battery life 3 years(25℃ below,replaced (Type CR2450))
  • Installation mode din rail
05

BD-DV Series DC Voltage Transducer

2024-11-14
  • Measurement   1-phase DC Voltage
  • Accuracy   Class 0.5
  • Input   0~75mV/0~10V/0~300V DC
  • Output   4~20mA/0~20mA DC or 0~5V/0~10V DC
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V DC
  • Wiring   1-phase 2-wire
  • Applicaiton Paired with PLC for Industrial Automation; Used for Metering
  • Response Time   ≤400ms
  • Installation 35mm DIN Rail/Screw fixed
  • Standard&Certificate   CE
06

BD-DI Series DC Current Transducer

2024-11-14
  • Measurement   1-phase DC Current
  • Accuracy   Class 0.5
  • Input   4~20mA/0~20mA DC
  • Output  4~20mA/0~20mA DC or 0~5V/0~10V DC
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V DC
  • Wiring   1-phase 2-wire
  • Applicaiton   Paired with PLC for Industrial Automation; Used for Metering
  • Response Time  ≤400ms
  • Installation  35mm DIN Rail/Screw fixed
  • Standard&Certificate   CE
07

BD-AV Series Single Phase AC Voltage Transducer

2024-11-14
  • Measurement 1-phase AC Voltage
  • Accuracy   Class 0.5
  • Input   0~120V/0~300V/0~500V AC
  • Output 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V DC
  • Wiring   1-phase 2-wire
  • Applicaiton   Paired with PLC for Industrial Automation; Used for Metering
  • Response Time ≤400ms
  • Installation  35mm DIN Rail/Screw fixed
  • Standard&Certificate  CE
08

AIM-D100-T Series Insulation Monitoring Device

2024-11-14
  • Auxilliary Power DC 9~36V
  • Maximum power comsumption ≤6W
  • Voltage range AIM-D100-TH: DC 100~1000V;AIM-D100-TL: DC 10~100V
  • Accuracy 0.5
  • Overvoltage threshold ≥110% Rated Voltage
  • Undervoltage threshold ≤90% Rated Voltage
  • Insulation resistance range 1kΩ~10MΩ
  • Warning and alarm range 10kΩ~10MΩ 
09

BD-3(4)V3 3P3W 3P4W AC Voltage Transducer

2024-11-14
  • Measurement   3-phase AC Voltage
  • Accuracy   Class 0.5
  • Input   0~120V/0~300V/0~500V AC
  •  Output   4~20mA/0~20mA DC or 0~5V/0~10V DC
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
  • Wiring   3-phase 3-wire,3-phase 4-wire
  • Applicaiton  Paired with PLC for Industrial Automation; Used for Metering
  •  Response Time  ≤400ms
  • Installation 35mm DIN Rail/Screw fixed
  • Standard&Certificate  CE
10

BD-3(4)P/Q/I 3P3W 3P4W PQ Combination Transducer

2024-11-14
  • Measurement   3-phase AC Active&Reactive Power (Range: -866~+866W)
  • Accuracy   Class 0.5
  •  Input   0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
  • Output   4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
  • Wiring   3-phase 3-wire,3-phase 4-wire
  • Applicaiton   Paired with PLC for Industrial Automation; Used for Metering
  • Response Time   ≤400ms
  •  Installation   35mm DIN Rail/Screw fixed
  •  Standard&Certificate   CE
11

ARD3M Series Motor Protection Relay

2024-11-14
● Suitable for motors with rated...
12

BD-3(4)P 3P3W 3P4W Reactive Power Transducer

2024-11-14
  • Measurement   3-phase AC Active Power (Range: 0~+866W)
  • Accuracy   Class 0.5
  • Input 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
  • Output   4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
  • Power Supply   85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
  • Wiring   3-phase 3-wire,3-phase 4-wire
  • Applicaiton   Paired with PLC for Industrial Automation; Used for Metering
  • Response Time   ≤400ms
  • Installation   35mm DIN Rail/Screw fixed
  • Standard&Certificate   CE
13

ARD2M Series Motor Protection Relay

2024-11-14
● U, I, P, S, PF, F, EP, Leakage...
14

BA50L-AI 0-1A Leakage Current Transducer

2024-11-14
  • Input   0~(0.1~1)A AC
  • Output  4~20mAV/0~20mA DC
  • Power Supply  12V/24V DC
  • Perforation Hole Size φ50mm
  • Applicaiton   Paired with PLC for Industrial Automation
  • Accuracy   Class 0.5
  • Response Time   ≤350ms
  • Installation   35mm DIN Rail/Screw fixed
  • Standard&Certificate CE; TüV
15

BA50L(II)-AI 0-1A Split Type Leakage Current Transducer

2024-11-14
  • Aperture 50mm
  • Input 0~(0.1-1)A current
  • Output DC 4-20mA or DC 0-5V, 0-10V
  • Overload 1.2 times of rated value
  • Power supply DC12V/DC24V