0102030405
01
BA50-AI 0-600A AC Current Transducer
2024-11-14
- Input 0~(60~600)A AC
- Output 1~5V/0~5V DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ50mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
02
BA50(II)-AI 0-600A Split Type Current Transducer
2024-11-14
- Aperture 50mm
- Input 0~(60-600A) current
- Output DC 4-20mA or DC 0-5V, 0-10V
- Overload 1.2 times of rated value
- Power supply DC12V/DC24V
Inquiry
view
detail
03
BA20-AI 0-200A AC Current Transducer
2024-11-14
- Input 0~(40~200)A AC
- Output 4~20mA/0~20mA DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ20mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
04
BA20(II)-AI 0-200A Split Type AC Current Transducer
2024-11-14
- Aperture 20mm
- Input 0~(0.5-200)A current
- Output DC 4-20mA or DC 0-5V, 0-10V
- Overload 1.2 times of rated value
- Power supply DC12V/DC24V
Inquiry
view
detail
05
ARD2F Series Motor Protection Relay
2024-11-14
● U, I, P, S, PF, F, EP, Leakage...
Inquiry
view
detail
06
BA05-AI 0-10A AC Current Transducer
2024-11-14
- Input 0~(0.5~10)A AC
- Output 4~20mA/0~20mA DC
- Power Supply 12V/24V DC
- Perforation Hole Size φ5mm
- Applicaiton Paired with PLC for Industrial Automation
- Accuracy Class 0.5
- Response Time ≤350ms
- Installation 35mm DIN Rail/Screw fixed
- Standard&Certificate CE; TüV
Inquiry
view
detail
07
BM200-VR Series Potentiometer Input Isolated Barrier
2024-11-13
- Input 0-10KΩ(Minimum Monitoring Range 1KΩ,Support 2-Wire 3-Wire)
- Output 4~20mA/0~20mA DC or 0~5V/0~10V/1~5V/2~10V
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
08
BM200-TR Series Thermal Resistance Input Isolated Barrier
2024-11-13
- Input Pt100: -200℃~850℃(minimum range 50℃),0~10KΩ(minimum range 1KΩ)
- Output 0~20mA /4~20mA (safe side output); Load resistance: ≤550Ω,0~5V/0~10V/1~5V/2~10V (safe side output); Load resistance: ≥30KΩ
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
09
BM200-DV Series Current Input Isolated Barrier
2024-11-13
- Input DC 0-5V/1-5V/0-10V/2-10V,Distribution voltage ≥10V/20mA
- Output 4~20mA/0~20mA/0-5V/1-5V/0-10V/2-10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
10
BM200-DI Series Current Input Isolated Barrier
2024-11-13
- Input 4~20mA/0~20mA DC,Distribution voltage ≥14V/20mA
- Output 4~20mA/0~20mA DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
11
BM100-VR Series Potentiometer Input Analog Signal Isolator
2024-11-13
- Input 0-10KΩ(maximum monitoring range is 1KΩ,support 2-Wire/3-Wire
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
12
BM100-TR Series Thermal Resistance Input Analog Signal Isolator
2024-11-13
- Input PT100(maximum 50℃,support 2-Wire and 3-Wire)
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤1s
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
13
BM100-DV Series Voltage Input Analog Signal Isolator
2024-11-13
- Input 0~5V/1~5V/0~10V/2~10V DC
- Output 4~20mA/0~20mA DC or 0~5V/1~5V/0~10V/2~10V DC
- Power Supply DC 20-35V OR AC/DC 85~265V
- Applicaiton Paired with PLC for Industrial Automation; Used for isolating signals
- Response Time ≤5ms
- Installation 35mm DIN Rail
- Standard&Certificate CE
Inquiry
view
detail
14
AMC96 Series 96*96 Digital Ammeter/Voltmeter
2024-11-09
● Current,voltage measurement;LE...
Inquiry
view
detail
15
AMC72 Series 75*75 DC Digital Ammeter/Voltmeter
2024-11-09
● DC Current,voltage measurement...
Inquiry
view
detail